ANQ-0217Degraded

Life Sciences · East US 2 · cluster detail

Customer
Life Sciences
Subscription
sub-anq-clusters-prod
Region
East US 2
Zone layout
Zonal · Zone 1
Blob SKU
Hot · ZRS
Nodes
4
VM SKU
Standard_L16s_v3
Qumulo version
7.2.2
Environment
Prod
Risk72· Lsv3 family · generation v2 (tiers to Blob) · local time America/New_York
Active alerts
4
2 paging
Read latency p95
20.8ms
Alert above 20 ms
Capacity used
64%
61 of 96 TiB
Busiest data disk
77%
disk-anq-c0217-data-01
Nodes online
4/4
0 evictions in 24 h · fully protected
Blob availability
98.29%
Lowest of 5 accounts
Likely Azure-causedAzure

Symptom at Oct 5, 14:16 UTC: File system read latency p95 rising: 9.3 → 20.8 ms. Scheduled Event preceded it by 6 min on vm-anq-c0217-n02: Freeze (platform): Host update: memory-preserving maintenance, VM paused 9 s. 3 more Azure signals nearby. No control plane operation in the 2 hours before.

Shared timeline

Azure (Service Health, Resource Health, Scheduled Events, Activity Log, metrics), Qumulo events and symptoms, and control plane operations on one axis.

  1. Oct 5, 14:18 UTCAzureAzure Monitor
    Blob ServerBusyError and ServerTimeoutError, 1.8% of transactions
  2. Oct 5, 14:16 UTCQumuloSymptom
    File system read latency p95 rising: 9.3 → 20.8 ms
  3. Oct 5, 14:10 UTCQumuloNode heartbeat
    n02: Node unresponsive for 9 s while the VM was paused; below the 30 s eviction threshold, not evicted
  4. Oct 5, 14:10 UTCAzureScheduled Event
    Freeze (platform): Host update: memory-preserving maintenance, VM paused 9 s
  5. Oct 5, 14:10 UTCAzureActivity Log
    Platform maintenance (memory-preserving) (platform-initiated)
  6. Oct 5, 13:38 UTCAzureService Health
    Service issue 7KT4-9QZ: Degraded performance for Premium SSD v2 managed disks (East US 2)

Alerts · 4 active, 2 resolved

RuleSeveritySincePages
File system p99 latency > threshold per SKU for ≥ 10 min
rg-anq-prod-eus2-c0217
p99 45.8 ms vs 45 ms for L16s_v3
Sev 2
Oct 5, 14:26 UTC
Active 4 min
Yes
Blob Availability < 99.9% over 5 min
stanq0217data02
Availability 98.29%
Sev 2
Oct 5, 14:23 UTC
Active 7 min
Yes
Service Health incident in a region with ANQ clusters
East US 2
7KT4-9QZ: Degraded performance for Premium SSD v2 managed disks
Sev 2
Oct 5, 13:38 UTC
Active 52 min
No
Blob ServerBusyError / ServerTimeoutError > 0 for ≥ 5 min
stanq0217data02
ServerBusyError 13.3/min, ServerTimeoutError 2/min
Sev 3
Oct 5, 14:23 UTC
Active 7 min
No
VmAvailabilityMetric < 1 for ≥ 1 min
vm-anq-c0217-n02
VmAvailabilityMetric 0.85 during Freeze
Sev 2
Oct 5, 14:11 UTC
Resolved 14:12 UTC
Yes
Any Scheduled Event received
vm-anq-c0217-n02
Freeze · Host update: memory-preserving maintenance, VM paused 9 s
Sev 3
Oct 5, 14:09 UTC
Resolved 14:11 UTC
No
PagerDuty
  • Q1M4RX8 ANQ-0217 read latency p95 above 20 msHigh · Triggered · 14:18 UTC

File system latency

Qumulo telemetry · read and write p95, all-op p99

Read p9520.8 msWrite p9527.9 msp9945.8 msp99 alert · L16s_v3 45 ms

Data disk consumed

Azure Monitor · 12 Premium SSD v2 data disks, % of provisioned

Busiest disk IOPS77%Busiest disk bandwidth61.2%Average IOPS64.4%Alert 95%

Nodes · 4

NodeVMStateVM availabilityCPUCPU stealDisk throttlingFloating IPsLast Scheduled Event
n01vm-anq-c0217-n01
VM running
Provisioning succeeded
139%0.8%77%3None in 30 days
n02vm-anq-c0217-n02
VM running
Provisioning succeeded
min 0.8561%21.4%71.4%3
Freeze · Completed
Oct 5, 14:10 UTC
n03vm-anq-c0217-n03
VM running
Provisioning succeeded
155%0.4%75.5%3
Freeze · Completed
Sep 12, 06:04 UTC
n04vm-anq-c0217-n04
VM running
Provisioning succeeded
131%0.5%69.7%3None in 30 days